¾íÁ±Ãŵç»ú²»Æô¶¯¹ÊÕϵÄÌØÕ÷¼°Åųý·½·¨
¾íÁ±ÃÅÓþÃÁËÒ²»á·ºÆð¾íÁ±ÃÅ¿¨×¡¡¢¿ªÆôÀú³ÌÀ§ÄÑ¡¢²»Ë³³©¡¢·¢³öÄæ¶úµÄÉùÒô¡¢ÃÅËø´ò²»¿ª»òÊÇÔ¿³×²å²»½øÈ¥µÈ¹ÊÕÏ£¬Ôڴ˽²½²¼ÃÄϾíÁ±Ãŵç»ú²»Æô¶¯¹ÊÕϵÄÌØÕ÷ÒÔ¼°Åųý·½·¨°É¡£
The rolling shutter door may also be stuck, difficult to open, unsmooth, make a harsh noise, the door lock cannot be opened or the key cannot be inserted after being used for a long time. Let's talk about the characteristics of the failure of Jinan rolling shutter door motor not starting and the troubleshooting.
¾íÁ±Ãŵç»ú²»Æô¶¯µÄ¹ÊÕÏÌØÕ÷
Fault characteristics of roller shutter door motor not starting
1¡¢Ïß·¶Ï·
1. Line open circuit
2¡¢µçÈÝ»÷´©(µ¥Ïà)
2. Capacitance breakdown (single phase)
3¡¢µç»úÏßȦ¶Ì·
3. Motor coil short circuit
4¡¢ÇÅʽÕûÁ÷Æ÷»÷´©
4. Breakdown of bridge rectifier
5¡¢Ðг̿ª¹Ø´¥µãÑõ»¯
5. Oxidation of travel switch contacts
6¡¢¼ÌµçÆ÷»ò½Ó´¥Æ÷´¥µãÑõ»¯»òÕ´ÎÛ
6. Oxidation or contamination of relay or contactor contacts
7¡¢°´Å¥¿ª¹Ø´¥µãÑõ»¯»òÕ´ÎÛ
7. Oxidation or contamination of button switch contacts
8¡¢µç»ú¹ýÈÈ¡¢Èȱ£»¤¶¯Æ÷Ðж¯
8. Motor overheating, thermal protection actuator action
9¡¢¹ýÈȱ£»¤Æ÷ʧЧ
9. Failure of overheat protector
10¡¢Öƶ¯Æ÷ճס
10. Brake stuck
11¡¢¼ÌµçÆ÷»ò½»Á÷½Ó´¥Æ÷ÏßȦ¶Ï·
11. Open circuit of relay or AC contactor coil
12¡¢µç´ÅÏßȦÖƶ¯Æ÷¿¨ËÀ
12. The solenoid brake is stuck
µç»ú²»Æô¶¯µÄ¹ÊÕÏÅųýÒªÁì
Troubleshooting for motor not starting
1¡¢½Óͨ»Ø·
1. Switch on the circuit
2¡¢¸ü»»µçÈÝ(µ¥Ïà)
2. Replace capacitance (single-phase)
3¡¢¸ü»»µç»ú
3. Replace the motor
4¡¢¸ü»»ÇÅʽÕûÁ÷Æ÷
4. Replace bridge rectifier
5¡¢´òÄ¥´¥µãÑõ»¯²ã¼°ÎÛÎï
5. Polish the contact to remove oxide layer and dirt
6¡¢´òÄ¥´¥µãÑõ»¯²ã¼°ÎÛÎï
6. Polish the contact to remove oxide layer and dirt
7¡¢´òÄ¥´¥µãÑõ»¯²ã¼°ÎÛÎï
7. Polish the contact to remove oxide layer and dirt
8¡¢´ýµç»úζȽµµ½70¡æÒÔÏÂÔÙÆô¶¯
8. Restart when the motor temperature drops below 70 ¡æ
9¡¢¸ü»»¹ýÈȱ£»¤Æ÷(µç»úÄÚ)
9. Replace the overheat protector (inside the motor)
10¡¢À¶¯ËÙ½µÀ¸Ë»òÊÖÀ»·ÐÎÁ´Ìõ
10. Pull the drawdown rod or the hand pulled ring chain
11¡¢¸ü»»¼ÌµçÆ÷»ò½»Á÷½Ó´¥Æ÷ÏßȦ
11. Replace the relay or AC contactor coil
12¡¢¸ü»»µç´ÅÌúÏßȦ
12. Replace the solenoid coil
ÎÒÃÇÂÛÊöÁ˹ØÓÚ¾íÁ±ÃŲ»¿É¿ªÆôµÄÔÒòÆÊÎöÏ¢Õù¾ö¼Æ»®¡£Èç¹ûÄã¶ÔÎÒÃǵIJúÆ·¸ÐÐËȤ£¬¿ÉÒÔÖ±½Ó¹Ø×¢ÎÒÃÇÍøÕ¾£¬ÁôÑÔ»òÕßÖ±½Ó²¦´òµç»°ÁªÏµµ½ÎÒÃÇ£¡
We elaborated on the cause analysis and solution of the roller shutter door that cannot be opened. If you are interested in our products, you can directly follow our website , leave a message or call us directly!
ÏÂһƪ£º¾ÏúÉÌÑ¡¾íÁ±Ãų§¼ÒÒª¿¼Âǵ½¼¸µã ÉÏһƪ£ºÈçºÎ¿ØÖÆ·À»ð¾íÁ±ÃŵÄÏ»¬
ÔĶÁ/ Recommended reading
- ¼ÃÄϾíÁ±ÃÅ10 2024-12-03
- ³µ¿â¾íÁ±ÃŹÊÕϼ°Î¬ÐÞÒªÁì 2024-12-14
- ³µ¿â¾íÁ±ÃŵÄάÐ޺ͱ£ÑøÒªÁìÓÐÄÄЩ 2024-12-07
- ¼ÃÄϾíÁ±ÃÅ£ºÃÅËøÉÏÁ˸ÃÔõô½âËø£¿ 2024-11-23
- ¼ÃÄϾíÁ±ÃÅ£º¶ÏµôһƬºóµÄ´¦ÀíÒªÁ죬Äãѧ»áÁËÂ𣿠2024-11-19
- ÈçºÎÑÓ³¤¾íÕ¢ÃŵÄÊÙÃü 2024-11-06
- ÖØÊÓ¾íÁ±ÃÅÃÅ¿Ú¶ÑÎïÎÊÌâ 2024-11-06
- ¿ìËÙ¾íÁ±ÃŽéÉÜÓë¿ìËÙ¾íÁ±ÃÅÖÊÁÏ˵Ã÷ 2024-10-26
¼ÃÄϾíÁ±ÃŵÄÊÂÇéÔÀí¼°×°ÖÃάÐÞ
2024-12-18
¼ÃÄϾíÁ±ÃÅÔÚ¼ÒÍ¥¡¢ÉÌÒµºÍ¹¤Òµ½¨ÖþÖлñµÃÁ˹㷺ӦÓã¬Æ书ЧÆëÈ«¡¢¿É¿¿¡¢ÃÀ¹ÛʵÓõÄÌصãʹÆä³ÉΪÃÅ´°×°ÊεÄÖÊÁÏ¡£¼ÃÄϾíÁ±ÃŽÓÄɸßÇ¿¶ÈÂÁºÏ½ðÖÊÁÏ£¬¾ß±¸¿¹·ç¡¢¿¹×²»÷ºÍ·ÀµÁÌØÐÔ£¬²¢Å䱸...