·À»ð¾íÁ±ÃÅ·Ö¼¸ÖÖÀà±ð£¿
Ò»ÊÇ°´²ÄÖÊ·Ö£¬¿É·ÖΪ¸ÖÖÊ·À»ð¾íÁ±ÃÅ¡¢¸´ºÏ·À»ð¾íÁ±ÃÅ¡¢ÎÞ»ú·À»ð¾íÁ±Ãŵȣ»
Firstly, according to the material, it can be divided into steel fire-resistant rolling shutter doors, composite fire-resistant rolling shutter doors, inorganic fire-resistant rolling shutter doors, etc;
¶þÊÇ°´×°ÖÃÐÎʽ¿É·ÖΪǽÖзÀ»ð¾íÁ±ÃÅ¡¢Ç½²à·À»ð¾íÁ±ÃÅ£»
Secondly, according to the installation form, it can be divided into fire-resistant rolling shutter doors in the wall and fire-resistant rolling shutter doors on the wall side;
ÈýÊÇ°´¿ªÆôÆ«Ïò¿É·ÖΪÉϾí·À»ð¾íÁ±ÃÅ¡¢²à¾í·À»ð¾íÁ±ÃÅ¡£
Thirdly, it can be divided into upper roll fireproof rolling shutter doors and side roll fireproof rolling shutter doors according to the opening direction.
·À»ð¾íÁ±ÃÅÆ·¼¶Ö÷ÒªÓÐËÄÖÖ£¬»®·ÖÊÇÒ»¼¶¡¢F2¼¶¡¢F3¼¶ÒÔ¼°F4¼¶£¬ÆäµÄÄÍ»ðʱ¼äÊÇ1.50h¡¢2.0h¡¢3.0h¡¢4.0h¡£
There are four main levels of fireproof rolling shutter doors, namely Level 1, F2, F3, and F4, with a fire resistance time of 1.50 hours, 2.0 hours, 3.0 hours, and 4.0 hours.
Ò»¡¢·À»ð¾íÁ±ÃÅÒ»°ãÔÚʲôµØ·½ÉèÖã¿
1¡¢ Where are fireproof rolling shutter doors usually installed?
ÒÀ¾Ý¹¤ÒÕ¾ö¶¨µÄ£¬·À»ð¾íÁ±ÃųýÉèÖÃÔÚ·À»ðǽÍ⣬ÔÚÁ½¸ö·À»ð·ÖÇøÖ®¼äûÓзÀ»ðǽµÄÒ²Ó¦ÉèÖ÷À»ð¾íÁ±¡£Ò»°ãÉèÔÚÒÔϲ¿Î»¡£
According to the process decision, in addition to being installed on the firewall, fire-resistant rolling shutter doors should also be installed between two fire compartments without a firewall. Generally located in the following areas.
1¡¢¹Ø±ÕÊèɢ¥ÌÝ£¬Í¨Ïò×ßµÀ£»¹Ø±ÕµçÌݼ䣬ͨÏòÇ°ÊÒ¼°Ç°ÊÒͨÏò×ßµÀµÄÃÅ¡£
1. Enclosed evacuation stairs leading to walkways; Enclosed elevator room with doors leading to the front room and the hallway.
2¡¢µçÀ¾®¡¢¹ÜµÀ¾®¡¢ÅÅÑ̵À¡¢À¬»øµÀµÈÊúÏò¹ÜµÀ¾®µÄ¼ì²éÃÅ¡£
2. Inspection doors for vertical pipeline shafts such as cable shafts, pipeline shafts, smoke exhaust ducts, and garbage lanes.
3¡¢»®·Ö·À»ð·ÖÇø£¬¿ØÖÆ·ÖÇø½¨ÖþÃæ»ýËùÉè·À»ðǽºÍ·À»ð¸ôǽÉϵÄÃÅ¡£µ±½¨ÖþÎïÉèÖ÷À»ðǽ»ò·À»ðÃÅÓÐÀ§ÄÑʱ£¬ÒªÓ÷À»ð¾íÁ±ÃÅÈ¡´ú£¬Í¬Ê±ÐëÓÃˮĻ±£»¤¡£
3. Divide fire zones, control the building area of the zones, and install firewalls and doors on fire partitions. When it is difficult to install firewalls or fire doors in buildings, fire-resistant rolling shutter doors should be used instead, and water curtains should be used for protection.
¶þ¡¢·À»ð¾íÁ±ÃŵÄ×°ÖÃÒªÇóºÍʹÓÃ˵Ã÷
2¡¢ Installation requirements and usage instructions for fireproof rolling shutter doors
1¡¢×°ÖþíÁ±ÃŵĶ´¿ÚÉϲ¿²»µÃÉèÓÐͨ·ç¹Ü¡¢Ë®¹ÜµÈ¡£
1. The upper part of the opening for installing the rolling shutter door shall not be equipped with ventilation pipes, water pipes, etc.
2¡¢¾íÁ±ÃÅ×°Öúúó£¬×°Öõõ¶¥£¬µõ¶¥±ßÑØÓ¦ÀëÁ±°å50mm£¬ÒÔÃâĦ²Á¡£
2. After the installation of the roller shutter door, install the ceiling, and the edge of the ceiling should be 50mm away from the curtain plate to avoid friction.
3¡¢µ÷ÊÔ¼°Ê¹ÓÃʱ£¬ÑϽûµ×²¿ Õ¾ÈË¡£µçÆ÷ÉèÊ©²»µÃÉÃ×Ô²ð°á¡£
3. During debugging and use, it is strictly prohibited to stand at the bottom. Electrical facilities shall not be dismantled or moved without authorization.
4¡¢Æ¾¾ÝÏû·ÀÖÎÀí»®¶¨Ã¿¼¾¶ÈÔÚÀýÐÐÏû·À¼ì²éʱһ¶¨Òª²»¿É©¼ìÆô¶¯µç»úµÄÁ´ÌõÈó»¬ÓÍ£¬ÕâÒ²ÊÇÐí¶àÎïÒµµ¥Î»£¬»òÕßÏû·Àµ¥Î»ÔÚ¼ì²éʱÊ詵ÄÒ»¸öÖØÒª»·½Ú¡£
4. According to the fire safety management regulations, it is necessary to not miss the inspection of the chain lubricating oil of the starting motor during the routine fire safety inspection every quarter. This is also an important link that many property management units or fire protection units neglect during the inspection.
±¾ÎÄÓɼÃÄϾíÁ±ÃÅÓÑÇé¹±Ï×.¸ü¶àÓйصÄ֪ʶÇëµã»÷:Õæ³ÏµÄ̬¶È.ΪÄúÌṩΪµÄЧÀÍ.¸ü¶àÓйصÄ֪ʶÎÒÃǽ«»á½ÐøÏò¸÷È˹±Ï×.¾´ÇëÆÚ´ý.
This article is dedicated by Jinan Roller Shutter Door. For more information, please click: Sincere attitude. We will provide you with comprehensive service. We will gradually contribute more relevant knowledge to everyone. Stay tuned
ÔĶÁ/ Recommended reading
- ¼ÃÄϾíÁ±ÃÅ10 2024-12-03
- ³µ¿â¾íÁ±ÃŹÊÕϼ°Î¬ÐÞÒªÁì 2024-12-14
- ³µ¿â¾íÁ±ÃŵÄάÐ޺ͱ£ÑøÒªÁìÓÐÄÄЩ 2024-12-07
- ¼ÃÄϾíÁ±ÃÅ£ºÃÅËøÉÏÁ˸ÃÔõô½âËø£¿ 2024-11-23
- ¼ÃÄϾíÁ±ÃÅ£º¶ÏµôһƬºóµÄ´¦ÀíÒªÁ죬Äãѧ»áÁËÂ𣿠2024-11-19
- ÈçºÎÑÓ³¤¾íÕ¢ÃŵÄÊÙÃü 2024-11-06
- ÖØÊÓ¾íÁ±ÃÅÃÅ¿Ú¶ÑÎïÎÊÌâ 2024-11-06
- ¿ìËÙ¾íÁ±ÃŽéÉÜÓë¿ìËÙ¾íÁ±ÃÅÖÊÁÏ˵Ã÷ 2024-10-26
¼ÃÄϾíÁ±ÃÅÔÚ¼ÒÍ¥¡¢ÉÌÒµºÍ¹¤Òµ½¨ÖþÖлñµÃÁ˹㷺ӦÓã¬Æ书ЧÆëÈ«¡¢¿É¿¿¡¢ÃÀ¹ÛʵÓõÄÌصãʹÆä³ÉΪÃÅ´°×°ÊεÄÖÊÁÏ¡£¼ÃÄϾíÁ±ÃŽÓÄɸßÇ¿¶ÈÂÁºÏ½ðÖÊÁÏ£¬¾ß±¸¿¹·ç¡¢¿¹×²»÷ºÍ·ÀµÁÌØÐÔ£¬²¢Å䱸...