µç¶¯¾íÕ¢ÃÅÒ£¿ØÆ÷ÅäÖÃÒªÁì
³£Óõĵ綯ÃÅÒ£¿Øϵͳһ°ã·Ö·¢ÉäºÍ½ÓÊÕÁ½¸ö²¿·Ö¡£
The commonly used electric door remote control system is generally divided into two parts: transmitting and receiving.
(1)·¢É䲿·Ö
(1) Launch part
·ÖΪң¿ØÆ÷ºÍ·¢ÉäÄ£¿é£¬Ò£¿ØÆ÷ÊÇ×÷Ϊһ¸öÕû»úÀ´¶ÀÁ¢Ê¹ÓÃ;¶øÒ£¿ØÄ£¿éÔÚµç·Öе±Ò»¸öÔª¼þÀ´Ê¹Óã¬Æ¾¾ÝÆäÒý½Å½ç˵½øÐÐÓ¦Óã¬Ê¹ÓÃÒ£¿ØÄ£¿éµÄÓÅÊÆÔÚÓÚ¿ÉÒÔºÍÓ¦Óõç·ÌìÒÂÎÞ·ìµÄÁ¬½Ó¡¢Ìå»ýС¡¢µÍ¡¢ÎᄀÆäÓ㬵«Ê¹ÓÃÕß±ØÐëÕæÕýÃ÷°×µç·ÔÀí£¬²»È»ÕÕ¾ÉÓÃÒ£¿ØÆ÷À´µÄ±ãµ±¡£
It is divided into remote controller and transmitting module. The remote controller is used independently as a whole machine; The remote control module is used as a component in the circuit and is applied according to its pin definition. The advantage of using the remote control module is that it can be seamlessly connected with the application circuit, small volume, low price and make the best use of everything. However, the user must really understand the circuit principle. Otherwise, it is convenient to use the remote control.
(2)½ÓÊÕ²¿·Ö
(2) Receiving part
·ÖΪ³¬Íâ²îÓ볬ÔÙÉú½ÓÊÕ·½·¨£¬³¬ÔÙÉú½âµ÷µç·Ҳ³Æ³¬ÔÙÉú¼ì²¨µç·£¬Ëüʵ¼ÊÉÏÊÇÊÂÇéÔÚ¼äЪÕñµ´×´Ì¬ÏµÄÔÙÉú¼ì²¨µç·¡£³¬Íâ²îʽ½âµ÷µç·Ó볬Íâ²îÊÕÒô»úÏàͬ£¬ËüÊÇÉèÖÃÒ»±¾»úÕñµ´µç·±¬·¢Õñµ´Ðźţ¬Óë½ÓÊÕµ½µÄÔØƵÐźŻìƵºó£¬»ñµÃÖÐƵ(Ò»°ãΪ465kHz)Ðźţ¬¾ÖÐƵ·Å´óºÍ¼ì²¨£¬½âµ÷³öÊý¾ÝÐźš£ÓÉÓÚÔØƵƵÂÊÊÇÀι̵ģ¬ËùÒÔÆäµç·Ҫ±ÈÊÕÒô»ú¼ò¼òµ¥Ð©¡£³¬Íâ²îʽµÄ½ÓÊÕÆ÷Îȶ¨¡¢ÁéÃô¶È¸ß¡¢¿¹×ÌÈÅÄÜÁ¦Ò²Ïà¶Ô½ÏºÃ;³¬ÔÙÉúʽµÄ½ÓÊÕÆ÷Ìå»ýС¡¢×ÔÖÆ¡£
Super regenerative demodulation circuit is also called super regenerative detection circuit. It is actually a regenerative detection circuit working in intermittent oscillation state. Superheterodyne demodulation circuit is the same as superheterodyne radio. It is equipped with a local oscillation circuit to generate oscillation signal. After mixing with the received carrier frequency signal, the intermediate frequency (generally 465kHZ) signal is obtained. After intermediate frequency amplification and detection, the data signal is demodulated. Because the carrier frequency is fixed, its circuit is simpler than that of a radio. The superheterodyne receiver has the advantages of stability, high sensitivity and relatively good anti-interference ability; Super regenerative receiver is small and cheap.
Ó°ÏìÎÞÏßµçʽµç¶¯¾íÕ¢ÃÅÒ£¿ØÆ÷Ò£¿Ø¾àÀëµÄÒòËØ£º
Factors affecting the remote control distance of radio electric rolling gate remote controller:
a.×èµ²£¬Ä¿Ç°Ê¹ÓõÄÎÞÏßÒ£¿ØÆ÷ʹÓû®¶¨µÄUHFƵ¶Î£¬ÒÔÖ±ÏßÁ÷´«£¬ÖмäÈôÓÐǽ±Ú×èµ²½«ÕÛËðÒ£¿Ø¾àÀ룬Èç¹ûÊǸֽî»ìÄàÍÁµÄǽ±Ú£¬ÓÉÓÚµ¼Ìå¶Ôµç²¨µÄÎüÊÕ×÷Óã¬Ó°ÏìÓúÉõ;
a. Blocking: the currently used wireless remote controller uses the UHF frequency band specified by the state and propagates in a straight line. If there is a wall blocking in the middle, the remote control distance will be damaged. If it is a reinforced concrete wall, it will be even more affected due to the absorption of electric waves by conductors;
b.·¢É书ÂÊ£¬·¢É书ÂÊ´óÔò¾àÀëÔ¶£¬µ«ºÄµç´ó£¬ÈÝÒ×±¬·¢×ÌÈÅ;
b. Transmission power: large transmission power means long distance, but it consumes a lot of power and is prone to interference;
c.½ÓÊÕÁéÃô¶È£¬½ÓÊÕÆ÷µÄ½ÓÊÕÁéÃô¶ÈÌá¸ß£¬Ò£¿Ø¾àÀëÔö´ó£¬µ«ÈÝÒ×ÊÜ×ÌÈÅÔì³ÉÎ󶯻òʧ¿Ø;
c. Receiving sensitivity: the receiving sensitivity of the receiver is improved, and the remote control distance is increased, but it is easy to be disturbed, resulting in misoperation or out of control;
d.ÌìÏߣ¬½ÓÄÉÖ±ÏßÐÍÌìÏߣ¬²¢ÇÒÏ໥ƽÐУ¬Ò£¿Ø¾àÀëÔ¶£¬µ«Õ¼¾Ý¿Õ¼ä´ó£¬ÔÚʹÓÃÖаÑÌìÏßÀ³¤¡¢ÀÖ±¿ÉÔö¼ÓÒ£¿Ø¾àÀë;
d. The antenna adopts linear antennas, which are parallel to each other and have a long remote control distance, but occupy a large space. Lengthening and straightening the antenna in use can increase the remote control distance;
e.¸ß¶È£¬ÌìÏßÔ½¸ß£¬Ò£¿Ø¾àÀëÔ½Ô¶£¬µ«Êܿ͹ÛÌõ¼þÏÞÖÆ¡£
e. Height, the higher the antenna, the farther the remote control distance, but it is limited by objective conditions.
µç¶¯¾íÕ¢ÃÅÒ£¿ØÆ÷¼¼ÊõÐÔÄÜ£º
Technical performance of remote controller for electric rolling gate:
1¡¢ÊÂÇéµçѹ£ºÒ£¿ØºÐAC220V£¬Ò£¿ØÆ÷DC12V(23AÐ͵ç³Ø)¡£
1. Working voltage: remote control box AC220V, remote controller DC12V (23a battery).
2¡¢¸ºÔع¦ÂÊ£º≤200VA¡£
2. Load power: ≤ 200va.
3¡¢Ò£¿Ø¾àÀ룺≤100Ãס£
3. Remote control distance: ≤ 100m.
4¡¢Ò£¿ØÀàÐÍ£ºÎÞÆ«ÏòÐÔ£¬¿É´©Ç½Ô½±Ú¡£
4. Remote control type: non directional, can pass through the wall.
5¡¢Ò£¿Ø·½·¨£º315MHz 6Íò×é±àÂ룬²úÆ·Ö®¼ä»¥²»×ÌÈÅ¡£
5. Remote control mode: 315MHz 60000 groups of codes, and products do not interfere with each other.
6¡¢ÍâÐγߴ磺ң¿ØºÐ130×85×35mm£¬Ò£¿ØÆ÷60×40×13mm¡£
6. Overall dimension: remote control box 130 × eighty-five × 35mm, remote control 60 × forty × 13mm¡£
µç¶¯¾íÕ¢ÃÅÒ£¿ØÆ÷ÊÂÇéƵÂÊÓë±àÂ룺
Working frequency and code of remote controller of electric rolling gate:
µç¶¯ÃÅÒ£¿Ø³£ÓõÄÔز¨ÆµÂÊΪ315mHz»òÕß433mHz£¬Ò£¿ØÆ÷ʹÓõÄÊÇ»®¶¨µÄ¿ª·ÅƵ¶Î£¬ÔÚÕâһƵ¶ÎÄÚ£¬·¢É书ÂÊСÓÚ10mW¡¢ÁýÕÖ¹æģСÓÚ100m»ò²»Áè¼Ý±¾µ¥Î»¹æÄ£µÄ£¬¿ÉÒÔ²»±Ø¾¹ý“ÎÞÏßµçÖÎÀíίԱ»á”ÉóÅú¶ø×ÔÓÉʹÓá£
The common carrier frequency of electric door remote control is 315MHz or 433MHz. The remote controller uses the open frequency band specified by the state. In this frequency band, if the transmission power is less than 10MW, the coverage is less than 100m or does not exceed the scope of the unit, it can be used freely without the approval of the "Radio Regulatory Commission".
ÏÂһƪ£ºÈçºÎÅäÖþíÁ±ÃÅÒ£¿ØÆ÷ѧÎÊ´ó×ÅÄØ ÉÏһƪ£º·À»ð¾íÁ±ÃÅͻȻ²»ÊÂÇéÁËÊÇÔõô»ØÊ£¿
ÔĶÁ/ Recommended reading
- ¼ÃÄϾíÁ±ÃŵÄÓŵãÆÊÎö 2024-12-16
- ¼ÃÄϾíÁ±ÃŵÄ×°ÖÃÖ¸ÄÏ£º°ì·¨Óë×¢ÒâÊÂÏî 2024-12-11
- ¼ÃÄϾíÁ±ÃŵÄάÐÞ±£Ñø£ºÑÓ³¤Ê¹ÓÃÊÙÃüµÄÒªº¦ 2024-12-09
- ¼ÃÄϾíÁ±ÃÅ£º¾íÁ±ÃÅÒ£¿ØÆ÷ʧÁéʱÊÔÊÔ±¾ÎĵÄÒªÁì°É£¡ 2024-11-16
- µç¶¯¾íÁ±ÃŵÄÓÅÊÆ 2024-11-12
- ¼ÃÄϾíÁ±ÃÅ£º¾íÁ±ÃÅÒ£¿ØÆ÷ʧÁéÔõô°ì£¿ 2024-09-02
- ¼ÃÄϾíÁ±Ãų§£º¾íÁ±ÃÅ¿¨Ö÷ÁËÔõô°ì 2024-08-28
- ¼ÃÄϵ綯¾íÁ±ÃÅ£ºµç¶¯¾íÕ¢ÃÅûµçÁËÔõô¿ª? 2024-08-28
³µ¿â¾íÁ±ÃŹÊÕϼ°Î¬ÐÞÒªÁì
2024-12-23
¡¡¡¡³µ¿â¾íÁ±ÃÅÔÚʹÓÃÀú³ÌÖпÉÄÜ»áÓöµ½ÖÖÖÖ¹ÊÕÏ£¬ÒÔÏÂÊÇһЩ³£¼ûµÄ¹ÊÕϼ°ÆäάÐÞÒªÁ죺¡¡¡¡Garage rolling shutter doors may encounter vario...