µç¶¯¾íÁ±Ãų£¼û¹ÊÕϼ°Î¬ÐÞÒªÁì

À´Ô´£º ÈÕÆÚ£º2023-02-18 Ðû²¼ÈË£º
һЩ³§·¿½ø³ö³µÁ¾µÄ´óÃÅ £¬ÒÔ¼°Ò»Ð©×¡Õ¬µÄ³µ¿â¶¼»áÓõ½µç¶¯¾íÁ±ÃÅ¡£ËùÒÔ³§¼Ò¾­³£½Óµ½¼ÃÄϵ綯¾íÁ±ÃÅÏà¹ØµÄάÐÞÐèÇó¡£½ñÌì¾ÍÒ»ÆðÀ´Á˽âϵ綯¾íÁ±Ãų£¼û¹ÊÕϼ°Î¬ÐÞÒªÁì°É¡£
Electric rolling shutter doors are used for the entrance and exit gates of vehicles in some factories and for the garages of some residential buildings. Therefore, the manufacturer often receives maintenance requirements related to Jinan electric roller shutter door. Let's learn about the common faults and maintenance methods of the electric roller shutter door today.
¿ØÖÆʧЧ¹ÊÕÏ
Control failure failure
¼ÌµçÆ÷(½Ó´¥Æ÷)´¥µãÕ³ËÀ¡¢ÐгÌ΢¶¯¿ª¹ØʧЧ»ò´¥Æ¬±äÐΡ¢»¬¿é½ô¶¨Âݶ¤ËÉ¡¢¿¿°åÂÝË¿ËÉʹ¿¿°åÒÆλ £¬Ê¹»¬¿é»òÂÝĸ²»¿ÉËæË¿¸Ëת¶¯¶øÒƶ¯¡¢ÏÞλÆ÷´«¶¯³ÝÂÖÆÆËð¡¢°´Å¥ÉÏ¡¢Ï¼ü¿¨ËÀ¡£
The relay (contactor) contact is stuck, the travel microswitch is invalid or the contact piece is deformed, the slider set screw is loose, the backup plate screw is loose, which causes the backup plate to move, so that the slider or nut cannot move with the screw rod rotation, the transmission gear of the limiter is damaged, and the upper and lower keys of the button are stuck.
¸ü»»¼ÌµçÆ÷(½Ó´¥Æ÷);¸ü»»Î¢¶¯¿ª¹Ø»ò´¥Æ¬;½ô¶¨»¬¿éÂݶ¤²¢Ê¹¿¿°å¸´Î»;¸ü»»ÏÞλÆ÷´«¶¯³ÝÂÖ;¸ü»»°´Å¥¡£
Replace the relay (contactor); Replace the microswitch or contact; Tighten the slider screw and reset the backup plate; Replace the transmission gear of the limiter; Replace the button.
µç¶¯»ú²»¶¯»òתËÙÂý¡£
The motor does not move or rotates slowly.
Ò»°ãÊÇÏß·¶Ï·¡¢µç»úÉÕËð¡¢Í£Ö¹°´Å¥Ã»¸´Î»¡¢ÏÞλ¿ª¹ØÐж¯¡¢¸ºÔؽϴóµÈÒýÆð¡£
Generally, it is caused by open circuit of the line, burning of the motor, failure to reset the stop button, action of the limit switch, large load, etc.
¼ì²éÏß·¡¢²¢½Óͨ;¸ü»»ÉÕËðµç»ú;¸ü»»°´Å¥»òÖظ´°´¶¯ÆµÆµ;²¦¶¯ÏÞλ¿ª¹Ø»¬¿éʹËüÍÑÀë΢¶¯¿ª¹Ø´¥µã £¬²¢µ÷½â΢¶¯¿ª¹ØλÖÃ;¼ì²é»úе²¿·ÖÓÐÎÞ¿¨×è £¬ÈôÓÐÔò¿¨×èÇåÀíÕÏ°­Îï¡£
Check the line and connect it; Replace the burnt motor; Replace the button or press it several times; Move the limit switch slider to separate it from the microswitch contact, and adjust the microswitch position; Check whether the mechanical part is jammed. If it is, remove the jamming and clear the obstacles.
¼ÃÄϵ綯¾íÁ±ÃÅ
ÊÖÀ­Á´²»¶¯¡£
The hand zipper does not move.
»·ÐÎÁ´Ìõ¶Âסʮ×Ö²Û;¼¬×¦ÎÞÍÑÀ뼬ÂÖ;ѹÁ´¼Ü¿¨ËÀ¡£
The annular chain blocks the cross groove; The pawl does not disengage from the ratchet; The chain holder is stuck.
Àí˳»·ÐÎÁ´Ìõ;µ÷½â¼¬×¦ÓëѹÁ´¼ÜÏà¶ÔλÖÃ;¸ü»»»òÈó»¬ÏúÖá¡£
Straighten the circular chain; Adjust the relative position of pawl and chain press frame; Replace or lubricate the pin shaft.
µç»úÕñ¶¯»òÔëÉù½Ï´ó¡£
The motor has large vibration or noise.
ɲ³µÅ̲»Æ½ºâ»ò¶ÏÁÑ;ɲ³µÅÌÎÞ½ô¹Ì;Öá³ÐʧÓÍ»òʧЧ;³ÝÂÖÄöºÏ²»Ë³¡¢Ê§ÓÍ»òÄ¥ËðÑÏÖØ;µç»úµçÁ÷Éù»òÕñ¶¯¡£
The brake disc is unbalanced or broken; The brake disc is not fastened; Bearing oil loss or failure; Gear engagement is not smooth, oil loss or serious wear; Motor current sound or vibration.
¸ü»»É²³µÅÌ»òÖØе÷½âƽºâ;½ô¹Ìɲ³µÅÌÂÝĸ;¸ü»»Öá³Ð;ÐÞÅäµç»úÖáÊä³ö¶Ë³ÝÂÖ¡¢È󻬻ò¸ü»»;¼ì²éµç»ú £¬Èçµç»ú»µËðÔò¸ü»»¡£
Replace the brake disc or readjust the balance; Tighten the brake disc nut; Replace the bearing; Repair, lubricate or replace the gear at the output end of the motor shaft; Check the motor and replace it if it is damaged.
ÒÔÉÏ×ÊÁÏÈç²»¿É½â¾öÄúµÄºâÓîÎÊÌâ £¬¿ÉÖ±½ÓÁªÏµÎ¬ÐÞµÄʦ¸µ×ÊÖú½â¾ö¡£Ò²¿ÉÒÔÏÈÀ´ÎÒÃÇÍøÕ¾ÁôÑÔ×Éѯ£¡
If the above information cannot solve your house problem, you can directly contact the maintenance technician for help. Or come to our website first Message consultation!

ÔĶÁ/ Recommended reading

¡¡¡¡³µ¿â¾íÁ±ÃÅÔÚʹÓÃÀú³ÌÖпÉÄÜ»áÓöµ½ÖÖÖÖ¹ÊÕÏ £¬ÒÔÏÂÊÇһЩ³£¼ûµÄ¹ÊÕϼ°ÆäάÐÞÒªÁ죺¡¡¡¡Garage rolling shutter doors may encounter vario...

¼ÃÄϾíÁ±ÃŵÄÓŵãÆÊÎö 2024-12-16
¼ÃÄϾíÁ±ÃŵÄ×°ÖÃÖ¸ÄÏ£º°ì·¨Óë×¢ÒâÊÂÏî 2024-12-11
¼ÃÄϾíÁ±ÃŵÄάÐÞ±£Ñø£ºÑÓ³¤Ê¹ÓÃÊÙÃüµÄÒªº¦ 2024-12-09
¼ÃÄϾíÁ±ÃÅ£º¾íÁ±ÃÅÒ£¿ØÆ÷ʧÁéʱÊÔÊÔ±¾ÎĵÄÒªÁì°É£¡ 2024-11-16
µç¶¯¾íÁ±ÃŵÄÓÅÊÆ 2024-11-12
¼ÃÄϾíÁ±ÃÅ£º¾íÁ±ÃÅÒ£¿ØÆ÷ʧÁéÔõô°ì£¿ 2024-09-02
¼ÃÄϾíÁ±Ãų§£º¾íÁ±ÃÅ¿¨Ö÷ÁËÔõô°ì 2024-08-28
¼ÃÄϵ綯¾íÁ±ÃÅ£ºµç¶¯¾íÕ¢ÃÅûµçÁËÔõô¿ª? 2024-08-28