1. ¼ì²éµçÔ´ºÍµç·£º¼ì²éµç¾íÁ±ÃŵĵçÔ´ÊÇ·ñÕý³£ £¬²¢¼ì²éµç·Á¬½ÓÊÇ·ñËɶ¯»ò¶Ì·¡£Ê¹ÓÃÍòÓñí»òµçѹ±íÕÉÁ¿µçÔ´µçѹÊÇ·ñÎȶ¨¡£

1. Check the power supply and circuit: First, check if the power supply of the electric roller shutter door is normal, and check if the circuit connection is loose or short circuited. Use a multimeter or voltmeter to measure whether the power supply voltage is stable.

¼ÃÄϾíÁ±Ãų§¼Ò

Jinan roller shutter door manufacturer

2. ¼ì²éµç»ú×Ô¼º£ºÈç¹ûµçÔ´ºÍµç·Õý³£ £¬¿ÉÄÜÊǵç»ú×Ô¼º·ºÆð¹ÊÕÏ¡ £¿ÉÒÔͨ¹ýÒÔÏ°취½øÐмì²é£º

2. Check the motor itself: If the power supply and circuit are normal, it may be a malfunction of the motor itself. The following steps can be used for inspection:

20221025022233112.jpg

a. ¼ì²éµç»úÊÇ·ñÕý³£ÔËת£º½«µç»úÖ±½ÓÁ¬½Óµ½µçÔ´ÉÏ £¬ÊÓ²ìµç»úÊÇ·ñÄܹ»Õý³£×ª¶¯¡£Èç¹û²»¿Éת¶¯ £¬¿ÉÄÜÊǵç»úÄÚ²¿Ë𻵠£¬ÐèÒª¸ü»»µç»ú¡£

a. Check if the motor is running properly: Connect the motor directly to the power supply and observe if the motor can rotate normally. If it cannot rotate, it may be due to internal damage to the motor, which needs to be replaced.

b. ¼ì²éµç»úÈÆ×éºÍ̼ˢ£º²ð¿ªµç»úÍâ¿Ç £¬¼ì²éµç»úÈÆ×éÊÇ·ñÓжÏÁÑ»òÉÕ»µµÄÇé¿ö¡£Í¬Ê±¼ì²éµç»úµÄ̼ˢÊÇ·ñÄ¥ËðÑÏÖØ £¬ÐèÒª¸ü»»¡£

b. Check the motor winding and carbon brush: Remove the motor casing and check if the motor winding is broken or burnt out. At the same time, check if the carbon brush of the motor is severely worn and needs to be replaced.

3. ¼ì²é¿ØÖÆÆ÷ºÍ¿ª¹Ø£ºÈç¹ûµç»ú×Ô¼ºÕý³£ £¬¿ÉÄÜÊÇ¿ØÖÆÆ÷»ò¿ª¹Ø¹ÊÕϵ¼Öµç»ú²»¿ÉÕý³£ÊÂÇé¡ £¿ÉÒÔͨ¹ýÒÔÏ°취½øÐмì²é£º

3. Check the controller and switch: If the motor itself is normal, it may be due to a malfunction in the controller or switch that prevents the motor from working properly. The following steps can be used for inspection:

a. ¼ì²é¿ØÖÆÆ÷ÊÇ·ñÊÂÇéÕý³££ºÊ¹ÓÃÍòÓñí»òµçѹ±í¼ì²é¿ØÖÆÆ÷ÊäÈëÊä³ö¶Ë¿ÚµÄµçѹÊÇ·ñÕý³£¡£Èç¹ûûÓеçѹÊä³ö»òÊäÈë²»Îȶ¨ £¬¿ÉÄÜÊÇ¿ØÖÆÆ÷¹ÊÕÏ £¬ÐèÒª¸ü»»¡£

a. Check if the controller is working properly: Use a multimeter or voltmeter to check if the voltage at the input and output ports of the controller is normal. If there is no voltage output or unstable input, it may be a controller malfunction that needs to be replaced.

b. ¼ì²é¿ª¹ØÊÇ·ñÕý³££º¼ì²éÃŵĿª¹ØÊÇ·ñÓÐËɶ¯»òËð»µÇé¿ö¡ £¿ÉÒÔʹÓÃÍòÓñí½øÐе¼Í¨²âÊÔ £¬È·± £¿ª¹ØÕý³£ÊÂÇé¡£

b. Check if the switch is normal: Check if the door switch is loose or damaged. A multimeter can be used for conductivity testing to ensure that the switch is working properly.

Èç¹ûÒÔÉÏÒªÁìÈÔÈ»ÎÞ·¨½â¾öÎÊÌâ £¬½¨ÒéÁªÏµµÄάÐÞÈËÔ±½øÐмìÐÞºÍά»¤¡£

If the above methods still cannot solve the problem, it is recommended to contact specialized maintenance personnel for inspection and maintenance.

ÔĶÁ/ Recommended reading

¡¡¡¡³µ¿â¾íÁ±ÃÅÔÚʹÓÃÀú³ÌÖпÉÄÜ»áÓöµ½ÖÖÖÖ¹ÊÕÏ £¬ÒÔÏÂÊÇһЩ³£¼ûµÄ¹ÊÕϼ°ÆäάÐÞÒªÁ죺¡¡¡¡Garage rolling shutter doors may encounter vario...

¼ÃÄϾíÁ±ÃŵÄÓŵãÆÊÎö 2024-12-16
¼ÃÄϾíÁ±ÃŵÄ×°ÖÃÖ¸ÄÏ£º°ì·¨Óë×¢ÒâÊÂÏî 2024-12-11
¼ÃÄϾíÁ±ÃŵÄάÐÞ±£Ñø£ºÑÓ³¤Ê¹ÓÃÊÙÃüµÄÒªº¦ 2024-12-09
¼ÃÄϾíÁ±ÃÅ£º¾íÁ±ÃÅÒ £¿ØÆ÷ʧÁéʱÊÔÊÔ±¾ÎĵÄÒªÁì°É£¡ 2024-11-16
µç¶¯¾íÁ±ÃŵÄÓÅÊÆ 2024-11-12
¼ÃÄϾíÁ±ÃÅ£º¾íÁ±ÃÅÒ £¿ØÆ÷ʧÁéÔõô°ì £¿ 2024-09-02
¼ÃÄϾíÁ±Ãų§£º¾íÁ±ÃÅ¿¨Ö÷ÁËÔõô°ì 2024-08-28
¼ÃÄϵ綯¾íÁ±ÃÅ£ºµç¶¯¾íÕ¢ÃÅûµçÁËÔõô¿ª? 2024-08-28
ÍøÕ¾µØͼ