Ë®¾§¾íÁ±Ãų£¼ûµÄ¼¸Ïî¹ÊÕϵÄÆÊÎöÒªÁì

À´Ô´£º ÈÕÆÚ£º2023-12-12 Ðû²¼ÈË£º

Ò»¡¢·À»ð¾íÁ±ÃŲ»¿É¶¯£º

1¡¢ Fireproof rolling shutter door does not operate:

Ó¦¼ì²éµçÔ´ £¬¿´·À»ð¾íÁ±ÃŵĵçÔ´¿Õ¿ªÊÇ·ñÓеç £¬Èç¹ûûµç £¬¾ÍÓ¦Ïß¼ì²éµçÔ´²¿·Ö¡£Èç¹ûÓеç £¬´Ëʱ¾íÁ±¿ØÖÆÏäµÄµçԴָʾµÆÓ¦µ±ÊÇÂÌÉ«³£ÁÁ¡£Èç¹ûָʾµÆ²»ÁÁ´ËʱÎÒÃÇÓ¦¼ì²é¿ØÖÆÏäÄڵıäѹÆ÷(±äѹÆ÷µÄµç×è270Å·Ä·)ÊÇ·ñÉÕ»µ¡£Èç¹ûµçԴָʾµÆÊÇÂÌÉ«ÉÁ˸ £¬±êÃ÷µçÔ´²¿·Ö¿ÉÄÜȱÏà £¬Èç¹ûµçÔ´²»È±ÏîÓпÉÄÜÊÇ¿ØÖÆÏäµÄ±¸ÓõçÔ´°åÉÕ»µ;Ò²ÓпÉÄÜסµçÔ´°åºÍ±¸ÓõçÔ´°å¶¼ÉÕ»µ¡£

The power supply should be checked to see if the power switch of the fireproof rolling shutter door has power. If there is no power, the power supply should be checked online. If there is electricity, the power indicator light of the roller shutter control box should be green and always on. If the indicator light is not on, we should check if the transformer (with a resistance of 270 ohms) inside the control box is burnt out. If the power indicator light is flashing green, it indicates that the power supply may be out of phase. If the power supply is not out of phase, it is possible that the backup power board of the control box is burnt out; It is also possible that both the residential power board and the backup power board are burnt out.

¶þ¡¢µçÔ´¿Õ¿ªÍƲ»ÉÏ£º

2¡¢ Power switch cannot be pushed up:

ËÍբʱ £¬¿Õ¿ªÍƲ»ÉÏÓ¦¼ì²é±¸ÓðåÊÇ·ñÓÐÎÊÌâ £¬±¸ÓðåµÄÊä³öÏߵĵç×èԼΪ300Å·Ä·¡£Èç¹û¿ªÂ·Ê±»ò¶Ì·Ӧ¸Ã¼ì²éµç»úµÄµãɲ³µÊÇ·ñÉÕ»µ £¬»ò¼ì²é±¸ÓðåÊÇ·ñÉÕ»µ¡£

When the air switch cannot be pushed up, check if there is a problem with the backup board. The resistance of the output line of the backup board is about 300 ohms. If there is an open circuit or a short circuit, check if the motor's point brake is burnt out, or check if the backup board is burnt out.

Èý¡¢²Ù×÷°´Å¥Ê¹Óò»Á飺

3¡¢ The operation button is not working properly:

Ó¦ÁìÏÈ°´ÏÂÍ£Ö¹¼ü £¬ÔÙ°´Ï¸´Î»¼ü £¬È»ºó°´ÉÏÐÐÏÂÐмü¡£

You should first press the stop button, then press the reset button, and then press the up and down buttons.

ËÄ¡¢µçÔ´¿ØÖÆÏä»ò°´Å¥Ãæ°åµÄָʾµÆÈ«ÁÁ£º

4¡¢ The indicator lights on the power control box or button panel are all on:

ÕâʱӦÏȼì²é°´Å¥ÏßÊÇ·ñÓжÌ·ÏÖÏó»òijһ¸ö°´Å¥±»Ñ¹ËÀµÄ¿ÉÄÜ £¬Èç¹ûÒÔÉÏÏÖÏó²»±£´æ £¬ÓпÉÄÜÊǵçÔ´Ö÷°åÉϵÄоƬ»µµô £¬ÕâʱӦ¸ü»»Ð¾Æ¬¡£×¢ÒâÒª·´×Å×° £¬(¼´¿ª¿Ú¶Ô×Å¿ª¿Ú)¡£

At this point, it is necessary to first check whether there is a short circuit in the button wire or the possibility of one button being pressed. If the above phenomena do not exist, it is possible that the chip on the power supply motherboard is damaged, and the chip should be replaced. Be sure to dress in the opposite direction (i.e. facing the opening).

20200630050916854.jpg

Î壺°´Å¥²Ù×÷Ö»ÓÐÉÏÐлòÏÂÐУº

5£º The button operation can only be up or down:

ÕâʱӦÏȼì²éÏÞλÏßÊÇ·ñÓеôÏßÏÖÏó £¬Èô¹ûûÓÐ £¬ÓпÉÄÜÊÇÖ÷µçÔ´°å»µÁË¡£

At this point, it is necessary to first check if there is any disconnection in the limit wire. If not, it is possible that the main power board is damaged.

Áù¡¢²Ù×÷°´Å¥Ç·ºÃÓûò°´Ê²Ã´°´Å¥¶¼ÊÇÏÂÐУº

6¡¢ The operation button is not easy to use or any button pressed will go down:

Ó¦Ïȼì²éÖ÷µç°åÓ뱸µç°åµÄÁ¬½ÓÅÅÏßʱÊÇ·ñËɶ¯¡£

First, check if the connection cables between the main and backup electrical boards are loose.

Æß¡¢Ôö¼ÓËø¿Ø£º

7¡¢ Add lock control:

Ö»ÐèÔÚÅÅÏߵĵÚ5ºÍ12µÄ¿ÕÉÏ´®½ÓÒ»¸öÔ¼1KµÄµç×è¡£

Just connect a resistor of approximately 1K in series on the 5th and 12th spaces of the ribbon cable.

°Ë¡¢Åжϵç»úµÄÓÅÁÓ£º

8¡¢ Judging the quality of the motor:

µç»úµÄÈýÏàµç×è´ï47-70Å·Ä·ÇÒÈýÏàƽºâ¡£ÈýÏ಻ƽºâ¿ÉÄÜÊǵç»ú»µÁË¡£

The three-phase resistance of the motor reaches 47-70 ohms and the three phases are balanced. Three phase imbalance may be due to motor failure.

¾Å¡¢·À»ð¾íÁ±Ãű¨¾¯Ê± £¬Ó¦ÁìÏÈÈ÷À»ð¾íÁ±ÃÅ×Ô¶¯Ï½µ¾¿¾¹ £¬Í¾Öв»Òª°´Èκΰ´Å¥ £¬È»ºóÔÙÉÏÐС£

9¡¢ When the fire shutter door alarms, the fire shutter door should be automatically lowered to the bottom first, and no buttons should be pressed during the process before going up.

Ê®¡¢·À»ð¾íÁ±ÃŵÄ×°Öõ÷ÊÔ£º

10¡¢ Installation and commissioning of fireproof rolling shutter doors:

ÔÚ×°Öõ÷ÊÔ֮ǰӦÏȼì²é¿ØÖÆÆ÷¡¢°´Å¥ºÐ¡¢¾íÃÅ»ú¡¢Ðг̿ª¹Ø¡¢µçɲ³µµÄÁ¬½ÓÏßÊÇ·ñÕý³£ £¬È·ÈϺóÔÚ½øÐе÷ÊÔ¡£

Before installation and debugging, it is necessary to check whether the connection wires of the controller, button box, rolling door machine, travel switch, and electric brake are normal, and then proceed with debugging after confirmation.

±¾ÎÄÓɼÃÄÏ·À»ð¾íÁ±ÃÅ×°ÖÃάÐÞÕûÀíÐû²¼ £¬ÄúÊDz»ÊǶÔÕâЩÄÚÈÝÓÐËùÁ˽âÁËÄØ?¸ü¶àµÄÄÚÈÝÇëµã»÷:http://www.jnyuqilin.comÎÒÃÇ»áÓиü¶à¾«²ÊÄÚÈݵÈÄã¼ì²ì

This article is compiled and published by the installation and maintenance of Jinan fireproof rolling shutter doors. Do you have any understanding of these contents? For more information, please click on: http://www.jnyuqilin.com We will have more exciting content waiting for you to view